Adegbesan Ololade O. & Olugbenga Babajide Soyemi, July 2020, Published: 2020-11-12
Finite Element Analysis software, ADINA was used to validate and compare the experimental work on the behaviour of Lytag-sand concrete T-beams in flexure. Three T-beams with concrete strengths of 27.5 N/mm2, 32.0 N/mm2 and 46 N/mm2 having one shear span-effective depth ratio a/d of 5.0 with longitudinal reinforcement percentages as 0.29%, 0.41% and 1.14% for beams were modelled with the truss model employed for the shear reinforcement. The beam has a web width of 102mm, flange width 306mm, flange thickness 76mm and height of the beam was 241mm. The span of the beam was 2.5m and having a projection of 0.25m beyond the supports. In the T-beams, shear– compression (V–C) failure mode characterized the beams. The failures mode of the beams was ductile with crushing of the concrete occurring in the flexural compression region and around the load and support plates. The results showed the dependence of the shear resistance of the beams on both the shear span-effective depth (a/d) ratio and the longitudinal steel percentage.